{"id":39034,"date":"2026-02-04T09:57:41","date_gmt":"2026-02-04T08:57:41","guid":{"rendered":"https:\/\/immunostep.com\/?p=39034"},"modified":"2026-02-04T11:48:00","modified_gmt":"2026-02-04T10:48:00","slug":"flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results","status":"publish","type":"post","link":"https:\/\/immunostep.com\/es\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/","title":{"rendered":"Flow cytometric detection of CAR-T cells: why two laboratories measure \u201cthe same thing\u201d and obtain different results"},"content":{"rendered":"<p data-start=\"417\" data-end=\"689\"><strong data-start=\"417\" data-end=\"466\">Flow cytometry-based detection of <a href=\"https:\/\/immunostep.com\/immunology\/car-t\/?v=12470fe406d4\">CAR-T cells<\/a><\/strong> is now a cornerstone in immunotherapy research, translational studies, and clinical monitoring. It is routinely used to assess <strong data-start=\"594\" data-end=\"660\">CAR-T expansion, persistence, phenotype, and functional status<\/strong> across multiple time points.<\/p>\n<p data-start=\"691\" data-end=\"916\">Yet, despite standardized protocols, similar panels, and experienced operators, it is remarkably common for <strong data-start=\"799\" data-end=\"881\">different laboratories to report inconsistent CAR-T frequencies and phenotypes<\/strong> when analyzing comparable samples.<\/p>\n<p data-start=\"918\" data-end=\"1252\">These discrepancies are rarely due to technical incompetence. Instead, they arise from <strong data-start=\"1005\" data-end=\"1049\">subtle but critical analytical decisions<\/strong> that profoundly influence sensitivity, specificity, and biological interpretation. Understanding these factors is essential for generating <strong data-start=\"1189\" data-end=\"1251\">robust, reproducible, and clinically meaningful CAR-T data<\/strong>.<\/p>\n<h2 data-start=\"1259\" data-end=\"1336\">1. Anti-CAR detection reagents: same target, different biological readouts<\/h2>\n<p data-start=\"1338\" data-end=\"1488\">One of the most underestimated sources of variability in <strong data-start=\"1395\" data-end=\"1437\">CAR-T cell detection by flow cytometry<\/strong> lies in the <strong data-start=\"1450\" data-end=\"1480\">anti-CAR detection reagent<\/strong> itself.<\/p>\n<p data-start=\"1490\" data-end=\"1618\">Although multiple reagents are marketed as \u201cCAR-specific,\u201d they rely on fundamentally different detection strategies, including:<\/p>\n<ul data-start=\"1619\" data-end=\"1723\">\n<li data-start=\"1619\" data-end=\"1649\">\n<p data-start=\"1621\" data-end=\"1649\"><strong data-start=\"1621\" data-end=\"1649\">Anti-idiotype antibodies<\/strong><\/p>\n<\/li>\n<li data-start=\"1650\" data-end=\"1683\">\n<p data-start=\"1652\" data-end=\"1683\"><strong data-start=\"1652\" data-end=\"1683\">Recombinant antigen ligands<\/strong><\/p>\n<\/li>\n<li data-start=\"1684\" data-end=\"1723\">\n<p data-start=\"1686\" data-end=\"1723\"><strong data-start=\"1686\" data-end=\"1723\">CAR-binding proteins or multimers<\/strong><\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1725\" data-end=\"1861\">Each of these approaches differs in <strong data-start=\"1761\" data-end=\"1836\">affinity, avidity, epitope accessibility, and conformational dependence<\/strong>, which directly affects:<\/p>\n<ul data-start=\"1862\" data-end=\"2062\">\n<li data-start=\"1862\" data-end=\"1929\">\n<p data-start=\"1864\" data-end=\"1929\">Detection of CAR-T cells with <strong data-start=\"1894\" data-end=\"1929\">low or transient CAR expression<\/strong><\/p>\n<\/li>\n<li data-start=\"1930\" data-end=\"2005\">\n<p data-start=\"1932\" data-end=\"2005\">Sensitivity to <strong data-start=\"1947\" data-end=\"2005\">partially internalized or non-functional CAR molecules<\/strong><\/p>\n<\/li>\n<li data-start=\"2006\" data-end=\"2062\">\n<p data-start=\"2008\" data-end=\"2062\">Background binding to activated non-transduced T cells<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2064\" data-end=\"2232\">As a result, two laboratories using different anti-CAR reagents may both be \u201cdetecting CAR-T cells,\u201d while in practice measuring <strong data-start=\"2193\" data-end=\"2231\">distinct biological subpopulations<\/strong>.<\/p>\n<h2 data-start=\"2328\" data-end=\"2390\">2. CAR expression is dynamic, not a fixed phenotypic marker<\/h2>\n<p data-start=\"2392\" data-end=\"2522\">Unlike lineage markers such as CD3 or CD45, <strong data-start=\"2436\" data-end=\"2472\">CAR expression is highly dynamic<\/strong> and tightly linked to cellular activation status.<\/p>\n<p data-start=\"2524\" data-end=\"2575\">Several factors modulate CAR surface detectability:<\/p>\n<ul data-start=\"2576\" data-end=\"2730\">\n<li data-start=\"2576\" data-end=\"2623\">\n<p data-start=\"2578\" data-end=\"2623\"><strong data-start=\"2578\" data-end=\"2623\">Antigen engagement and recent stimulation<\/strong><\/p>\n<\/li>\n<li data-start=\"2624\" data-end=\"2645\">\n<p data-start=\"2626\" data-end=\"2645\"><strong data-start=\"2626\" data-end=\"2645\">Tonic signaling<\/strong><\/p>\n<\/li>\n<li data-start=\"2646\" data-end=\"2686\">\n<p data-start=\"2648\" data-end=\"2686\"><strong data-start=\"2648\" data-end=\"2686\">Activation-induced internalization<\/strong><\/p>\n<\/li>\n<li data-start=\"2687\" data-end=\"2730\">\n<p data-start=\"2689\" data-end=\"2730\"><strong data-start=\"2689\" data-end=\"2730\">Ex vivo manipulation and resting time<\/strong><\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2732\" data-end=\"2952\">Consequently, CAR-T cells analyzed immediately after thawing, after short-term culture, or following antigen exposure may display <strong data-start=\"2862\" data-end=\"2912\">substantially different CAR signal intensities<\/strong>, even if cell numbers remain unchanged.<\/p>\n<p data-start=\"2954\" data-end=\"3008\">This dynamic behavior represents a major challenge in:<\/p>\n<ul data-start=\"3009\" data-end=\"3138\">\n<li data-start=\"3009\" data-end=\"3044\">\n<p data-start=\"3011\" data-end=\"3044\"><strong data-start=\"3011\" data-end=\"3044\">Longitudinal CAR-T monitoring<\/strong><\/p>\n<\/li>\n<li data-start=\"3045\" data-end=\"3082\">\n<p data-start=\"3047\" data-end=\"3082\"><strong data-start=\"3047\" data-end=\"3082\">Post-infusion follow-up studies<\/strong><\/p>\n<\/li>\n<li data-start=\"3083\" data-end=\"3138\">\n<p data-start=\"3085\" data-end=\"3138\"><strong data-start=\"3085\" data-end=\"3138\">Functional assays combined with immunophenotyping<\/strong><\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3140\" data-end=\"3294\">Without controlling for these variables, differences attributed to biological response may in fact reflect <strong data-start=\"3247\" data-end=\"3293\">temporal or activation-dependent artifacts<\/strong>.<\/p>\n<h2 data-start=\"3384\" data-end=\"3453\">3. Sensitivity versus specificity: a critical analytical trade-off<\/h2>\n<p data-start=\"3455\" data-end=\"3648\">Many laboratories prioritize <strong data-start=\"3484\" data-end=\"3507\">maximum sensitivity<\/strong> when detecting CAR-T cells, particularly in settings where CAR-T frequencies are expected to be low, such as late post-infusion time points.<\/p>\n<p data-start=\"3650\" data-end=\"3738\">However, increased sensitivity often comes at the expense of <strong data-start=\"3711\" data-end=\"3737\">analytical specificity<\/strong>.<\/p>\n<p data-start=\"3740\" data-end=\"3764\">Common pitfalls include:<\/p>\n<ul data-start=\"3765\" data-end=\"4031\">\n<li data-start=\"3765\" data-end=\"3802\">\n<p data-start=\"3767\" data-end=\"3802\">Overly permissive gating strategies<\/p>\n<\/li>\n<li data-start=\"3803\" data-end=\"3864\">\n<p data-start=\"3805\" data-end=\"3864\">Insufficient use of biologically relevant negative controls<\/p>\n<\/li>\n<li data-start=\"3865\" data-end=\"3957\">\n<p data-start=\"3867\" data-end=\"3957\">Failure to account for <strong data-start=\"3890\" data-end=\"3909\">spreading error<\/strong> from highly expressed neighboring fluorochromes<\/p>\n<\/li>\n<li data-start=\"3958\" data-end=\"4031\">\n<p data-start=\"3960\" data-end=\"4031\">Misinterpretation of low-intensity signals near the detection threshold<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4033\" data-end=\"4175\">The outcome is an apparent increase in CAR-T detection that may <strong data-start=\"4097\" data-end=\"4137\">not correlate with clinical outcomes<\/strong>, persistence, or functional readouts.<\/p>\n<p data-start=\"4177\" data-end=\"4360\">This sensitivity\u2013specificity imbalance is especially problematic in <strong data-start=\"4245\" data-end=\"4268\">multicenter studies<\/strong>, where small analytical differences can translate into major discrepancies across datasets.<\/p>\n<h2 data-start=\"4467\" data-end=\"4532\">4. Panel design: the hidden determinant of CAR-T detectability<\/h2>\n<p data-start=\"4534\" data-end=\"4700\">In high-dimensional <strong data-start=\"4554\" data-end=\"4588\">multiparametric flow cytometry<\/strong>, CAR detection never occurs in isolation. Instead, it is embedded within a broader <strong data-start=\"4672\" data-end=\"4699\">immunophenotyping panel<\/strong>.<\/p>\n<p data-start=\"4702\" data-end=\"4735\">Key panel design factors include:<\/p>\n<ul data-start=\"4736\" data-end=\"4967\">\n<li data-start=\"4736\" data-end=\"4787\">\n<p data-start=\"4738\" data-end=\"4787\">Fluorochrome choice for the CAR detection channel<\/p>\n<\/li>\n<li data-start=\"4788\" data-end=\"4854\">\n<p data-start=\"4790\" data-end=\"4854\">Relative antigen density of co-expressed markers (CD3, CD4, CD8)<\/p>\n<\/li>\n<li data-start=\"4855\" data-end=\"4904\">\n<p data-start=\"4857\" data-end=\"4904\">Spectral overlap and cumulative spreading error<\/p>\n<\/li>\n<li data-start=\"4905\" data-end=\"4967\">\n<p data-start=\"4907\" data-end=\"4967\">Interaction between bright and dim signals in complex panels<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4969\" data-end=\"5124\">A CAR detection reagent that performs optimally in a low-parameter panel may <strong data-start=\"5046\" data-end=\"5080\">lose resolution or specificity<\/strong> when incorporated into a 15\u201320 color panel.\u00a0Importantly, these failures are often <strong data-start=\"5164\" data-end=\"5174\">silent<\/strong>\u2014the data appear acceptable, but the biological signal is distorted.<\/p>\n<h2 data-start=\"5354\" data-end=\"5439\">5. Real-world consequences: from analytical variability to clinical interpretation<\/h2>\n<p data-start=\"5441\" data-end=\"5553\">Discrepancies in <strong data-start=\"5458\" data-end=\"5493\">flow cytometric CAR-T detection<\/strong> extend far beyond technical concerns. They directly affect:<\/p>\n<ul data-start=\"5554\" data-end=\"5773\">\n<li data-start=\"5554\" data-end=\"5616\">\n<p data-start=\"5556\" data-end=\"5616\">Correlation between CAR-T expansion and therapeutic response<\/p>\n<\/li>\n<li data-start=\"5617\" data-end=\"5665\">\n<p data-start=\"5619\" data-end=\"5665\">Assessment of CAR-T persistence and durability<\/p>\n<\/li>\n<li data-start=\"5666\" data-end=\"5716\">\n<p data-start=\"5668\" data-end=\"5716\">Comparability of results across clinical centers<\/p>\n<\/li>\n<li data-start=\"5717\" data-end=\"5773\">\n<p data-start=\"5719\" data-end=\"5773\">Interpretation of biomarkers in regulatory submissions<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"5775\" data-end=\"5936\">When two laboratories report different CAR-T frequencies from the same sample, the issue is not merely methodological\u2014it becomes <strong data-start=\"5904\" data-end=\"5935\">interpretative and clinical<\/strong>.<\/p>\n<h3>Conclusion<\/h3>\n<p data-start=\"5958\" data-end=\"6158\"><strong data-start=\"5958\" data-end=\"6037\">Flow cytometry remains a powerful and indispensable tool for CAR-T analysis<\/strong>, but its reliability depends on a deep understanding of the biological and technical variables that shape CAR detection.<\/p>\n<p data-start=\"6160\" data-end=\"6358\">Differences in <strong data-start=\"6175\" data-end=\"6253\">anti-CAR reagents, panel design, gating strategies, and biological context<\/strong> can all lead to divergent results, even when laboratories believe they are measuring the same parameter.\u00a0Recognizing and addressing these limitations is not a weakness of the method; it is a prerequisite for <strong data-start=\"6463\" data-end=\"6536\">robust, reproducible, and clinically meaningful CAR-T <a href=\"https:\/\/www.linkedin.com\/company\/36113352\/admin\/page-posts\/published\/\">data generation<\/a><\/strong>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Flow cytometry-based detection of CAR-T cells is now a cornerstone in immunotherapy research, translational studies, and clinical monitoring. It is routinely used to assess CAR-T expansion, persistence, phenotype, and functional status across multiple time points. Yet, despite standardized protocols, similar panels, and experienced operators, it is remarkably common for different laboratories to report inconsistent CAR-T [&hellip;]<\/p>\n","protected":false},"author":225,"featured_media":39035,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_links_to":"","_links_to_target":""},"categories":[2033],"tags":[2066,2496,2288,2031,2341,2492,2485,2170,2493,2494,2495],"class_list":["post-39034","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-immunology","tag-biomarkers","tag-cancer-immunotherapy-combination","tag-cancer-immunotherapy-combinations","tag-car-t","tag-car-t-cells","tag-cell-therapy","tag-clinical-cytometry","tag-flow-cytometry","tag-high-dimensional-flow","tag-oncology-research","tag-translational-research"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Flow cytometric detection of CAR-T cells: why two laboratories measure \u201cthe same thing\u201d and obtain different results | Immunostep Biotech<\/title>\n<meta name=\"description\" content=\"At Immunostep we have been innovating since 2001 to develop comprehensive products that contribute to improve.-CAR-T cells.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Flow cytometric detection of CAR-T cells: why two laboratories measure \u201cthe same thing\u201d and obtain different results | Immunostep Biotech\" \/>\n<meta property=\"og:description\" content=\"At Immunostep we have been innovating since 2001 to develop comprehensive products that contribute to improve.-CAR-T cells.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/\" \/>\n<meta property=\"og:site_name\" content=\"Immunostep Biotech\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/immunostepsl\/\" \/>\n<meta property=\"article:published_time\" content=\"2026-02-04T08:57:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-04T10:48:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/immunostep.com\/wp-content\/uploads\/2026\/02\/CART-CELLS.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"612\" \/>\n\t<meta property=\"og:image:height\" content=\"459\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"\u00c1ngela Cabestrero\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Immunostep\" \/>\n<meta name=\"twitter:site\" content=\"@Immunostep\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"\u00c1ngela Cabestrero\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/\"},\"author\":{\"name\":\"\u00c1ngela Cabestrero\",\"@id\":\"https:\/\/immunostep.com\/#\/schema\/person\/6f7086a7900eb41588a2465bcae5f427\"},\"headline\":\"Flow cytometric detection of CAR-T cells: why two laboratories measure \u201cthe same thing\u201d and obtain different results\",\"datePublished\":\"2026-02-04T08:57:41+00:00\",\"dateModified\":\"2026-02-04T10:48:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/\"},\"wordCount\":720,\"publisher\":{\"@id\":\"https:\/\/immunostep.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/immunostep.com\/wp-content\/uploads\/2026\/02\/CART-CELLS.jpg\",\"keywords\":[\"biomarkers\",\"Cancer Immunotherapy Combination\",\"cancer immunotherapy combinations\",\"CAR T\",\"CAR-T cells\",\"Cell Therapy\",\"clinical cytometry\",\"flow cytometry\",\"High Dimensional Flow\",\"Oncology Research\",\"Translational Research\"],\"articleSection\":[\"Immunology\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/\",\"url\":\"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/\",\"name\":\"Flow cytometric detection of CAR-T cells: why two laboratories measure \u201cthe same thing\u201d and obtain different results | Immunostep Biotech\",\"isPartOf\":{\"@id\":\"https:\/\/immunostep.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/immunostep.com\/wp-content\/uploads\/2026\/02\/CART-CELLS.jpg\",\"datePublished\":\"2026-02-04T08:57:41+00:00\",\"dateModified\":\"2026-02-04T10:48:00+00:00\",\"description\":\"At Immunostep we have been innovating since 2001 to develop comprehensive products that contribute to improve.-CAR-T cells.\",\"breadcrumb\":{\"@id\":\"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/#primaryimage\",\"url\":\"https:\/\/immunostep.com\/wp-content\/uploads\/2026\/02\/CART-CELLS.jpg\",\"contentUrl\":\"https:\/\/immunostep.com\/wp-content\/uploads\/2026\/02\/CART-CELLS.jpg\",\"width\":612,\"height\":459,\"caption\":\"3d illustration of a T cell attacking a cancer cell\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/immunostep.com\/es\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Flow cytometric detection of CAR-T cells: why two laboratories measure \u201cthe same thing\u201d and obtain different results\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/immunostep.com\/#website\",\"url\":\"https:\/\/immunostep.com\/\",\"name\":\"Immunostep Biotech\",\"description\":\"Innovating to deliver high-performance technology for Research and Diagnosis\",\"publisher\":{\"@id\":\"https:\/\/immunostep.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/immunostep.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/immunostep.com\/#organization\",\"name\":\"Immunostep Biotech\",\"url\":\"https:\/\/immunostep.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/immunostep.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/immunostep.com\/wp-content\/uploads\/2021\/10\/logo-web-color.png\",\"contentUrl\":\"https:\/\/immunostep.com\/wp-content\/uploads\/2021\/10\/logo-web-color.png\",\"width\":1299,\"height\":591,\"caption\":\"Immunostep Biotech\"},\"image\":{\"@id\":\"https:\/\/immunostep.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/immunostepsl\/\",\"https:\/\/x.com\/Immunostep\",\"https:\/\/www.linkedin.com\/company\/immunostepsl\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/immunostep.com\/#\/schema\/person\/6f7086a7900eb41588a2465bcae5f427\",\"name\":\"\u00c1ngela Cabestrero\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/immunostep.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/378033e78b9b0300f6f50aeac830c5cf?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/378033e78b9b0300f6f50aeac830c5cf?s=96&d=mm&r=g\",\"caption\":\"\u00c1ngela Cabestrero\"},\"url\":\"https:\/\/immunostep.com\/es\/author\/acabestrero\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Flow cytometric detection of CAR-T cells: why two laboratories measure \u201cthe same thing\u201d and obtain different results | Immunostep Biotech","description":"At Immunostep we have been innovating since 2001 to develop comprehensive products that contribute to improve.-CAR-T cells.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/","og_locale":"es_ES","og_type":"article","og_title":"Flow cytometric detection of CAR-T cells: why two laboratories measure \u201cthe same thing\u201d and obtain different results | Immunostep Biotech","og_description":"At Immunostep we have been innovating since 2001 to develop comprehensive products that contribute to improve.-CAR-T cells.","og_url":"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/","og_site_name":"Immunostep Biotech","article_publisher":"https:\/\/www.facebook.com\/immunostepsl\/","article_published_time":"2026-02-04T08:57:41+00:00","article_modified_time":"2026-02-04T10:48:00+00:00","og_image":[{"width":612,"height":459,"url":"https:\/\/immunostep.com\/wp-content\/uploads\/2026\/02\/CART-CELLS.jpg","type":"image\/jpeg"}],"author":"\u00c1ngela Cabestrero","twitter_card":"summary_large_image","twitter_creator":"@Immunostep","twitter_site":"@Immunostep","twitter_misc":{"Escrito por":"\u00c1ngela Cabestrero","Tiempo de lectura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/#article","isPartOf":{"@id":"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/"},"author":{"name":"\u00c1ngela Cabestrero","@id":"https:\/\/immunostep.com\/#\/schema\/person\/6f7086a7900eb41588a2465bcae5f427"},"headline":"Flow cytometric detection of CAR-T cells: why two laboratories measure \u201cthe same thing\u201d and obtain different results","datePublished":"2026-02-04T08:57:41+00:00","dateModified":"2026-02-04T10:48:00+00:00","mainEntityOfPage":{"@id":"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/"},"wordCount":720,"publisher":{"@id":"https:\/\/immunostep.com\/#organization"},"image":{"@id":"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/#primaryimage"},"thumbnailUrl":"https:\/\/immunostep.com\/wp-content\/uploads\/2026\/02\/CART-CELLS.jpg","keywords":["biomarkers","Cancer Immunotherapy Combination","cancer immunotherapy combinations","CAR T","CAR-T cells","Cell Therapy","clinical cytometry","flow cytometry","High Dimensional Flow","Oncology Research","Translational Research"],"articleSection":["Immunology"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/","url":"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/","name":"Flow cytometric detection of CAR-T cells: why two laboratories measure \u201cthe same thing\u201d and obtain different results | Immunostep Biotech","isPartOf":{"@id":"https:\/\/immunostep.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/#primaryimage"},"image":{"@id":"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/#primaryimage"},"thumbnailUrl":"https:\/\/immunostep.com\/wp-content\/uploads\/2026\/02\/CART-CELLS.jpg","datePublished":"2026-02-04T08:57:41+00:00","dateModified":"2026-02-04T10:48:00+00:00","description":"At Immunostep we have been innovating since 2001 to develop comprehensive products that contribute to improve.-CAR-T cells.","breadcrumb":{"@id":"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/#primaryimage","url":"https:\/\/immunostep.com\/wp-content\/uploads\/2026\/02\/CART-CELLS.jpg","contentUrl":"https:\/\/immunostep.com\/wp-content\/uploads\/2026\/02\/CART-CELLS.jpg","width":612,"height":459,"caption":"3d illustration of a T cell attacking a cancer cell"},{"@type":"BreadcrumbList","@id":"https:\/\/immunostep.com\/2026\/02\/04\/flow-cytometric-detection-of-car-t-cells-why-two-laboratories-measure-the-same-thing-and-obtain-different-results\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/immunostep.com\/es\/"},{"@type":"ListItem","position":2,"name":"Flow cytometric detection of CAR-T cells: why two laboratories measure \u201cthe same thing\u201d and obtain different results"}]},{"@type":"WebSite","@id":"https:\/\/immunostep.com\/#website","url":"https:\/\/immunostep.com\/","name":"Immunostep Biotech","description":"Innovating to deliver high-performance technology for Research and Diagnosis","publisher":{"@id":"https:\/\/immunostep.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/immunostep.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/immunostep.com\/#organization","name":"Immunostep Biotech","url":"https:\/\/immunostep.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/immunostep.com\/#\/schema\/logo\/image\/","url":"https:\/\/immunostep.com\/wp-content\/uploads\/2021\/10\/logo-web-color.png","contentUrl":"https:\/\/immunostep.com\/wp-content\/uploads\/2021\/10\/logo-web-color.png","width":1299,"height":591,"caption":"Immunostep Biotech"},"image":{"@id":"https:\/\/immunostep.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/immunostepsl\/","https:\/\/x.com\/Immunostep","https:\/\/www.linkedin.com\/company\/immunostepsl\/"]},{"@type":"Person","@id":"https:\/\/immunostep.com\/#\/schema\/person\/6f7086a7900eb41588a2465bcae5f427","name":"\u00c1ngela Cabestrero","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/immunostep.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/378033e78b9b0300f6f50aeac830c5cf?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/378033e78b9b0300f6f50aeac830c5cf?s=96&d=mm&r=g","caption":"\u00c1ngela Cabestrero"},"url":"https:\/\/immunostep.com\/es\/author\/acabestrero\/"}]}},"_links":{"self":[{"href":"https:\/\/immunostep.com\/es\/wp-json\/wp\/v2\/posts\/39034"}],"collection":[{"href":"https:\/\/immunostep.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/immunostep.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/immunostep.com\/es\/wp-json\/wp\/v2\/users\/225"}],"replies":[{"embeddable":true,"href":"https:\/\/immunostep.com\/es\/wp-json\/wp\/v2\/comments?post=39034"}],"version-history":[{"count":1,"href":"https:\/\/immunostep.com\/es\/wp-json\/wp\/v2\/posts\/39034\/revisions"}],"predecessor-version":[{"id":39037,"href":"https:\/\/immunostep.com\/es\/wp-json\/wp\/v2\/posts\/39034\/revisions\/39037"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/immunostep.com\/es\/wp-json\/wp\/v2\/media\/39035"}],"wp:attachment":[{"href":"https:\/\/immunostep.com\/es\/wp-json\/wp\/v2\/media?parent=39034"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/immunostep.com\/es\/wp-json\/wp\/v2\/categories?post=39034"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/immunostep.com\/es\/wp-json\/wp\/v2\/tags?post=39034"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}